Advertisements

Plastic Bodied Electromagnetic Flow meter

Plastic Bodied Electromagnetic Flow meter wmp series

The Plastic Bodied Electromagnetic Flow meter WMP-Series is a full-bore, plastic-bodied electromagnetic flow meter designed for flow and usage monitoring applications in 1, 2 and 3 inch pipe. The polypropylene flow tube offers corrosion resistance to a wide range of chemicals and fertilizers. It is light weight and easy to install or remove from the pipe for inspection.

With no moving parts, the Electromagnetic Flow meter permits unobstructed flow, minimizing flow disturbances and straight pipe requirements. The Electromagnetic Flow meter WMP Series can be used in piping configurations where there is little space between the meter and an elbow or valve. The Electromagnetic Flow meter WMP-Series is resistant to wear from sand and debris found in ground or surface water. Since there are no bearings or propeller to wear out, maintenance and repair costs are kept to a minimum and it tolerates high flows without damage.

A hinged polyethylene cover is included that protects from dust and UV rays, while permitting easy access to the flow rate and total display. The electronics housing can be fitted with cross-drilled screws and seal wire for tamper-evidence. Flow rate and total can be displayed in a variety of units, customer-selected and factory-set.

The Electromagnetic Flow meter  WMP 101 is externally powered via a 5-pin connector cable (20 ft/6m)which also provides pulse output for use with a variety of Seametrics and other displays and controls for remote reading, data logging, pulse-to analog conversion, and telemetry applications.The WMP104 is a battery-operated unit for use when pulse output is not required. The standard batteries are user replaceable with an approximate 1 year life depending on usage.

An extended battery life option  offers an estimated 2-4 year life depending on usage.In the event of DC power loss, or when changing batteries, the WMP will retain internal settings and flow total.

Specifications

  • Pipe Size :  1, 2, or 3 inch full port
  • Fittings : 1 inch NPTF, 2 or 3 inch flange clamps with 2 or 3 inch NPTF fitting kit
  • Pressure  : 150 psi or 10.3 bar working pressure @ 70˚ F
  • Operating Temperature Range :  Operating: 10˚ to 130˚ F (-12˚ to 54˚ C), Non-operating: -40˚ to 176˚ F (-40˚ to 80˚ C)
  • Accuracy : ±1% of reading (between 10% and 100% of maximum flow) , ±3% of reading (between cutoff and 10% of maximum flow)
  • Flow Range :
    • Minimum : 1”: 2.3 gpm (0.145 l/s) 2”: 6 gpm (0.38 l/s) 3”: 14 gpm (0.88 l/s)
    • Maximum :  1”: 110 gpm (6.94 l/s) 2”: 300 gpm (18.9 l/s) 3”: 670 gpm (42.3 l/s)
  • Materials :
    • Body  : Glass-filled polypropylene
    • Electrodes 316 stainless steel
    • Electronics Housing Power coated diecast aluminum
    • Display Cover Polyethylene
  • Display
    • Digits : Rate 6 digits, Total : 8 digits
    • Units Rate  : Gallons/Minute, Million Gallons/Day, Cubic Feet/Second,Cubic Feet/Minute, Liters/Second, Liters/Minute, Million Liters/Day, Cubic Meters/Minute, Cubic Meters/Hour
    • Units Total : Acre-Feet, Acre-Inch, Gallons, Gallons x 1000,  Cubic Feet, Liters, Mega liters, Cubic Meters,
      Cubic Meters x 1000
  • Security : Cross-drilled screws and tamper-evident seal (optional)
  • Power  :
    • WMP101 : 10–30 Vdc @ 60 mA maximum (15 mA average)
      Note: Using an unregulated power supply >18 Vdc may damage the meter due to AC line input voltage
      fluctuation.
    • WMP104 :  6 – AA 1.5V lithium cells, replaceable. Estimated life is 1 year depending on usage (standard)
      2 – C 3.6V lithium batteries, replaceable. Estimated life is 2–4 years depending on usage (extended battery life
      opt)
  • Pulse Output Signal (WMP101 only) Current sinking pulse, opto-isolated, 32 Vdc maximum @ 10mA maximum
  • Pulse Rate :
    • Low Frequency (-PxU) 1 unit/pulse out, pulse width of 10 ms, depending on unit selection
      (WMP101 only)
    • High Frequency (-HF) 1” 2” 3” Pulse width 1.1 ms, min–max frequency, 3–150 Hz
      Pulse/Gal 80 30 13
      Pulse/Liter 21.14 7.93 3.44
  • Empty Pipe Detection  : Hardware/software, conductivity based
  • Conductivity : >20 microSiemens/cm
  • Environmental : NEMA 3X, IP64
  • Electrical Connection (WMP101 only) 5-pin male circular connector, mates to industry standard cable

Dimensions

Dimensions shown without the Seametrics WMP Fitting Kit

Installation

   

More information please click

 

Advertisements

Recent Posts: Flow meters Wiratama

Rheonik Coriolis Mass Flow Meters

The Rheonik coriolis meters are primarily Mass Flow Meters and they can measure mass very accurately. These two components are RHM coriolis flow sensors and RHE Coriolis Flow Transmitters

Elektrogas Automatic Safety Solenoid Valves

Safety solenoid valves for air and gas from delta elektrogas has many models such as VMM, vmh, vmr, vml, and VMRNA

VMH Elektrogas Safety shut off valves for gas

The VMH type valve is a safety shut off valve for gas with a hydraulic actuator. It is suitable for air or gas blocking and releasing controls, required in the main pipe of gas power burners, atmospheric gas boilers, industrial kilns, and others gas-consuming appliances

Solenoid Valve Shako Pneumatics

SHAKO Pneumatics has dedicated its entire resources to the field of pneumatic products and committed its energies to develop and produce new products

Air Diaphragm Pumps

An Air Diaphragm Pumps is a type of positive displacement pump that uses compressed air as a power source.

Vane Air Motors and Air Gear Motors Tonson

Air Motors are designed to operate by compressed air. For applications, where positive braking is a requirement, a range of caliper brakes is offered.

Air Winches for lifting and pulling in Hazardous Area

An air winch is powered by compressed air instead of electricity. The drive mechanism of the air winch will begin to power the cable drum and effectively raising or lowering the attached load

Perlunya Resetting dan Kalibrasi Flow meter secara berkala

kalibrasi flow meter dimaksudkan untuk mengembalikan performa flow meter guna mendapatkan faktor ketidak pastian pengukuran, yang merupakan akurasi flow meter dengan flow caliberator dan resetting

Dimensi Flange ANSI

Dimensi Flange Ansi#150

VALCOM – PRESSURE SENSOR

Valon pressure sensor products, vpr2, vprv-d, VSW2, VPRT, VDP4, VFM, VPRH, VPMC, Pressure Meter

 

Ada yang ingin ditanyakan silahkan :

1. Jika ada Pertanyaan tentang Product ataupun harga silahkan langsung hubungi :

 .

2.  Jika ada pertanyaan atau diskusi Tentang tulisan ini silahkan email ke admin@rudywinoto.com

.

Atau silahkan isi kolom dibawah ini dan klik submit  

.  

 
About Rudy Wiratama (980 Articles)
rudywinoto.com/wmablog.com/flowmasonic.com
%d bloggers like this: