Seametrics-Brass Single Jet with Integral Display SEB Series

SEB Seametrics Low Flow Meter

The SEB is a plated brass low flow meter suited for clean water. It is available in 1/2” and 3/4” thread, with union type meter couplings for easy installation and service. This meter is ideal for flow rates between 0.2 GPM (0.76 LPM) and 18 GPM (68.14 LPM). The SEB has only one moving part, the propeller.

A 5-30 Vdc square wave output makes the SEB ideal for many industrial control applications. This signal interfaces easily with programmable logic controllers and computer input boards. SEB meters can also be used in conjunction with the Seametrics FT420 flow computer for reading flow rate and total flow, or AO55 for 4-20 mA output. For metering pump pacing applications, a standard PD10 pulse divider is recommended.

Features

  • Single-jet meter
  • Compact brass body
  • Union couplings
  • Easy installation and maintenance
  • Interfaces with many controls and displays

Features Seametrics SEB Single Jet

Baca juga: Seametrics Single Jet Low Flow Meter SPT & SPX Series

Applications

  • Industrial control operation
  • Low flow situations
  • Clean water

Specification

Sensor GMR 5-30 VDC Current sinking pulse
Fitting 1/2”, 3/4”—Male NPT union couplings
Materials Body Nikel-plated brass
Rotor Chamber
Brass
Rotor Thermoplastic
Shaft Tungsten carbide
Bearings Water-cooled thermoplastic
Maximum Temperature 185 ̊ F (85 ̊ C)
Maximum Pressure 175 psi (12 bar)
Cable #22 AWG 3-cond, 12′ maximum run 2,000′ (610 m)
Flow Range 1/2”: 0.2 – 10 GPM (0.76 – 37.85 LPM
3/4”: 0.2 – 18 GPM (0.76 – 68.14 LPM)
Standard K-Factor 1/2″ : 550 pulse per gallon
3/4″ : 330 pulses per gallon
Accuracy ± -1% of full scale
Regulatory EA MARKMark

*Specifications subject to change. Please consult our website for the most current data

Instalation and Maintance

Installation. Single-jet meters like the SEB are somewhat insensitive to upstream and downstream flow conditions. For best results, however, upstream and downstream straight pipe of five pipe diameters is recommended.

Maintenance. The SEB’s Hall-effect sensor and cap are field-replaceable.

Dimension

Dimension Seametrics SEB Single Jet

Diameter 1/2 Inch 3/4 Inch
A 2.5 2.5
B 9.2 10.4
C 2.8 2.8
D 4.35 5.1
E 3/4 in. BSPP 1 in. BSPP
F 1/2 NTP 3/4 NTP

Visit Wmablog for more info and price or