Valcom Istrument

Valcom logo

Since 1974 Valcom® designs, develops and manufactures instrumentation for measuring and control of storage of fluids and solids. Since the birth of Valcom® today many things have changed, and the company has been evolved in different aspects; from a logistical transfer and expansion of the sales department, it has followed the technological evolution that the company has always tried to encourage and drive, on one hand making of own property some technologies once entrusted to third parties, on the other focusing on the internal research and development department.

Valcom Product

Model Fuction Measuring Range Proses Temperature
T7N Series • Level Continous
• Pressure
-1∼ 0 bar
0 ∼1000 bar
Standard: -40 ∼ +85°C
Finned body: -40 ∼ +130°C
Capillary: -40 ∼ +280°C
T7D Series • Level Continous
• Differential Flow
-18 ∼ 18 mbar
-10000 ∼ 10000 mbar
Standard: -40 ∼ +85°C
Capillary: -40 ∼ +280°C
ASL Series Level On-Off (Switch) On-Off Switch Standard: -40 ∼ +85°C
Finned Body T1: -60 ∼ +150°C
Finned Body T2: -200 ∼ +450°C
MFM Series Flow Multiphase Variable (Multiphase) Standard: -40 ∼ +80
up to 283°C (On request)
MFU Series Flow Multiphase Variable (Multiphase) Standard: -40 ∼ +80
up to 283°C (On request)
WGE Sereis Flow Variable (Multiphase) WGE body: -40°∼ 280°C
With integral manifold: -40°C ∼ 180°C
SPG Series Gauge 0 ∼ 1(std) … up to 10 (optional) mH2O -20 ∼ +130°C
LSG Series Level On-Off (Switch) On-Off Switch Standard: -20 ∼ +85°C
Finned body: -40 ∼ +130°C
T7W Series Water in Oil 0 ∼ 45% Concentration of Water in Oil -10 ∼ +150°C
T76 Series • Level Continous
• Pressure
-1 ∼ 0 bar
0 ∼ 1000 bar
Standard: -40 ∼ +85°C
Finned body: -40 ∼ +130°C
Capillary: -40 ∼ +280°C
T79 Series • Level Continous
• Pressure
-1 ∼ 0 bar
0 ∼ 1000 bar
Standard: -40 ∼ +85°C
Finned body: -40 ∼ +130°C
Capillary: -40 ∼ +280°C
T7I Series • Level Continous
• Pressure
-1 ∼ 0 bar
0 ∼ 1000 bar
Standard: -40 ∼ +80…283°C
T7L Series Level Continous 0.6 ∼ 10 m Standard: -40 ∼ +85°C
Finned body: -40 ∼ +130°C
KRG Series Level Continous 0 ∼ 30 m Cone and Rod Antenna: -40 ∼ +150 °C
PTFE Antenna: -40 ∼ + 200 °C
T7T Series Temperature Standard: -40 ∼ +85°C
Nipple-Union-Nipple: Tmax = 150°C
Remote: Tmax = 350°C or 500°C
Standard: -40 ∼ +85°C
Nipple-Union-Nipple: -40 ∼ +150°C
Remote: -40 ∼ +500°C
T7B Series • Pressure
• Density
0.3 ∼ 10 m -100 ∼ +200°C (Finned: +350°C)
T7V series Accessories Not Applicable 4 ∼ 20 mA
T7C series Consistency 1.50 ∼ 12 % CS +5 ∼ +90°C
T7S series Density 0…250 g/l
0…3000 g/l
Standard: -10 ∼ +130°C
T7M Series Temperature 0∼50 (std)… up to 300(on request) °C Standard: -40 ∼ +85°C
OMD Series Oil Mist 0 ∼ 2 mg/l -20 ∼ 70 °C
T72 series Level Continous 0 ∼ 0,35 bar
0 ∼ 50 bar
-10 ∼ +80°C
BMS Series Systems Not Applicable Standard: -40 ∼ +85°C
HMI Series Systems Not Applicable Standard: +5 ∼ +60 °C
THP series Pressure Max: 0 ∼ 8 bar
Min: 0 ∼ 1.5 bar
-10 ∼ +80°C
18I series Level Continous 0 ∼ 1 bar
0 ∼ 100 bar
-10 ∼ +80°C
27A series Pressure -1 ∼ 0 bar
0 ∼ 1000 bar
Standard: -40 ∼ +85°C
Finned body: -40 ∼ +130°C
Capillary: -40 ∼ +280°C
M3 series Accessories Not Applicable Standard: -40 ∼ +85°C
27I series Level Continous -1 ∼ 0 bar
0 ∼ 1000 bar
-40 ∼ +85°C
27D series • Level Continuous
• Differential Pressure
-0.1 ∼ 0 bar
0 ∼ 16 bar
Standard: -40 ∼ +85°C
Capillary: -40 ∼ +280°C
27L series Level Continuous Starting from 0 ∼ 0.5 m Standard: -40 ∼ +85°C
Finned body: -40 ∼ +130°C
86A series • Level Continuous
• Pressure
< ± 0.25 % FS -40 ∼ +85°C
27M series Pressure 0 ∼ 0.003 bar
0 ∼ 16 bar
-40 ∼ +85°C
JBX series Accessories Not Applicable -20 ∼ +125°C
LSG-02 series Level On-Off (Switch) On-Off Switch Standard: -20 ∼ +85°C
Glass Reed Relay: -40 ∼ +130°C
TSU series Accessories Not Applicable -20 ∼ +55°C
VCM series Accessories Not Applicable Standard: -40 ∼ +85°C
M1 series Accessories Not Applicable Standard: -40 ∼ +85°C
M2 series Accessories Not Applicable Standard: -40 ∼ +85°C
M5 series Accessories Not Applicable Standard: -40 ∼ +85°C
HART® Server Software
Accessories
Not Applicable Not Applicable

Be the first to comment