Paperless recorder PR10

The new PR series paperless recorders are launched in full product range with outstanding specifications and features. PR series includes a low-cost PR10, a popular PR20 and a high-end PR30. Compared with the first generation VR series, PR series offers much more, for example recorders in 4.3” & 12.1” displays in addition to 5.6”, 100 msec. sampling rate, external channels, batch, custom display, more strict FDA 21 CFR part 11, handwriting messages, SD slot, 2 USBs, pulse input, field calibration, Web Server, email, 19 languages, IP65, and yet in shorter depth 167mm.

PR10 -  paperless recorder


  • Touch Screen, TFT, 65K color
  • 100 msec. scan rate
  • Internal memory: 256 MB Flash
  • CPU: ARM Cortex-A8, 1Ghz
  • Standard: Ethernet, SD slot & USB
  • Option: RS232/422/485 & Pulse input
  • Protection: IP65 front & IP20 rear
  • Standards: CE, cULus & RoHS
  • Pulse input for flow applications
  • Direct Printer connectivity
  • Webserver & Email directly from Recorder
  • Remote IO channels, Virtual channels
  • Master & Slave, Modbus RTU and TCP protocols
  • Custom display pages similar to HMI
  • Batch operations, built in security & FDA 21 CFR part 11
  • 19 international languages


Product position low-cost one, good for replacing 6-dotting chart
recorders, and 1, 2, 3 pen recorders
Input numbers 3, 6 channels
True universal inputs Thermocouples: J, K, T, E, B, R, S, N, L, U, P, W5, W3, LR, A1, A2, A3, M
RTD: Pt50, Pt100, Pt200, Pt500, Pt1000 (α=0.00385), Pt50, Pt100 (α=0.00391)Cu10 (α=0.00427), Cu50, Cu100(α=0.00426, 0.00428), Ni100, Ni200, Ni500,JPt50, JPt100, JPt200, JPt500, JPt1000 (α=0.003916)Ni1000 (α=0.00617) mA, V, mV
The fastest sampling rate to reach 100 msec / dot, default setting at 1 sec / dot
Math, External channels, Batch,
Custom display, FDA 21 CFR part 11
only available by Plus versions
Display 4.3″ TFT wide touch screen
Resolution 480 x 272
MTFB backlight at 25°C 30,000 hrs
Backlight LED
Screen saver, Email Yes
A faster CPU ARM Cortex-A8, 1Ghz
Internal Flash memory 256 MB
RAM 256 MB
Ethernet Modbus TCP/IP
RS-232/422/485 optional RS-232 or RS-422/485 Modbus RTU
SD card Slot, USB host x 2 standard, one USB in the front, another USB in the back
Pulse input optional DI card offering either logic or high frequency pulse counter
START / STOP key to start / stop record and to turn off the display only, not recorder itself so that a quick start possible
Calibration correction on-site calibration possible, or using handy features of Offset and Gain for correction
Multilingual convenient for local users by offering 19 languages including English, Japanese,Danish, Italian, Polish, Russian, Dutch, Korean, Thai, Turkish, Portuguese,Chinese(simplied, traditional), French, German, Spanish, Swedish,Brazil Portuguese, Czech, other languages negotiable
PC software Historical Viewer+ Configuration standard
Extensive software Data Acquisition Studio optional real-time monitoring
Power supply 90-250VAC or 11-36VDC
Outer dimensions (W x H x L mm) 144 x 144 x189
Shorter mounting depth (mm) 171
DIN Panel cutout (W x H mm) 137 x 137
Protection IP65 front, IP20 rear
Operating temperature 0°C to 50°C
Storage temperature -30°C to 70°C
Safety standards to be available CE, cULus, RoHS

Articles: Flow meters Wiratama

Flow meter ultrasonic 2 Path

Flow meter ultrasonic 2 path atau Double path merupakan jenis flow meter ultrasonic clamp on yang bisa di operasikan atau di instalasi di 2 pipa dengan ukuran dimeter pipa  yang sama maupun ukuran dimeter pipa yang berbeda. Jadi jika kita ingin mengetahui atau mengecek aliran suatu cairan dalam pipa dengan ukuran pipa berbeda ataupun sama […]

Flow meter Clamp On Ultrasonic

Flow meter clamp on ultrasonic adalah jenis flow meter yang cara kerjanya menggunakan ultra sound dan cara instalasinya cukup dengan di clamp pada permukaan pipa. Yang dimaksud dengan cara instalasi clamp on adalah saat melakukan instalasi kita tidak perlu memotong pipa maupun melubangi pipa. Dengan melakukan pemotongan pipa atau melubangi pipa, akan menghambat proses produksi […]

Flow Meter Open Channel

Open Channel Flow meter is a flow meter used to measure a flow in an open system wher the flow is due to a height difference such as the flow of water in the river or channel. Flow meter open channel adalah flow meter yang dapat diaplikasikan untuk mengukur aliran dengan kapasitas yang sedang seperti […]

Mengukur Debit Air Pada Kapasitas Aliran Besar

Dalam mengukur debit air pada kapasitas aliran besar mempunyai banyak implikasi terhadap jenis alat ukur atau flow meter, akurasi hasil pengukuran , biaya investasi, waktu instalasi dan maintenance alat ukurnya. Debit air dengan kapasitas aliran besar biasanya banyak di gunakan pada pembangkt lisatrik dalam hal ini biasanya PLTU dan PLTA, Produksi air minum (PDAM) dan […]

Rotary Paddle Level Switch Parker JC7

A level switch is a device used to detect the level of substances such as liquid, chemical solvent, powders, lumps within tanks, silos, and hoppers. In addition, a level switch prevents overfilling of tanks and silos and ensures tanks do not run too low, possibly interrupting production. JB series Rotary Paddle Level Switch Features : […]


Ada yang ingin ditanyakan silahkan :

1. Jika ada Pertanyaan tentang Product ataupun harga silahkan langsung hubungi :


2.  Jika ada pertanyaan atau diskusi Tentang tulisan ini silahkan email ke


Atau silahkan isi kolom dibawah ini dan klik submit  



Leave a Reply

Fill in your details below or click an icon to log in: Logo

You are commenting using your account. Log Out / Change )

Twitter picture

You are commenting using your Twitter account. Log Out / Change )

Facebook photo

You are commenting using your Facebook account. Log Out / Change )

Google+ photo

You are commenting using your Google+ account. Log Out / Change )

Connecting to %s

%d bloggers like this: