Coriolis Flow Transmitter RHE

Inside the measuring sensor, there are precision tubes that are energized by an electromagnetic drive system, which itself is fed by the transmitter, to vibrate at their natural frequencies. When a liquid or gas flows through the vibrating tubes, it is subjected to additional deflection due to the degree of inertia that is generated. This deflection is recorded electronically by two velocity sensors and a high-precision electronic time delta. This measured quantity is proportional to the mass flow rate.

Coriolis mass Flow Controls

A further conversion into physical units is done in a purely digital manner using a signal processor in the transmitter. At the same time, all of the appliance’s functions are constantly monitored. Should any disruptions occur, all of the errors that have occurred are immediately reported in the display.

The transmitter has a 4 to 20 mA analogue output with programmable span, which is proportional either to the measured mass flow rate or the temperature; it also has an impulse output that supplies mass-proportional impulses. All of the outputs and measuring functions can be verified at any time by the user by using the diagnostic mode in the appliance. The maintenance or new calibration intervals can be monitored via a run-time counter. For service or repair purposes, the transmitter and flow sensor can be replaced independently of each other.

Coriolis mass flow Transmitter

This significantly reduces the costs of spare parts for the installed flow sensor/transmitter. During the factory calibration, the mass flow sensor can be calibrated independently of the transmitter. All sensor-specific calibration data can be programmed using magnetic switches located on the front panel. To achieve this, the instrument does not need to be opened. All of the relevant data is buffered in a non-volatile semiconductor device (EEPROM).

The RHEONIK mass flow meter consists of one of the RHM series flow sensors and one RHE series transmitter. The remote unit RHE 07/08 is for installation in a safe non-Ex area and is connected to the sensor via a single multi-conductor cable. Please note, that the types RHE 07/08 and all sensor articles are available in non Ex-versions (without Exnameplate). The RHE 11 (Ex d) may be installed and operated in hazardous Ex-areas (Zone 1 or 2). Ex-series sensors RHM (with Ex-Label) are, when connected with an Ex- Transmitter, made for installation inside hazardous areas (Ex-zone 0, 1 or 2). The transmitter RHE includes seven printed boards which can be replaced during servicing. The remote electronic unit consists of two bent measuring loops in the shape of an omega.

Kind of Coriolis Flow Transmitter

  • RHE 07

The RHEONIK mass flow meter consists of one of the RHM series flow sensors and one RHE series transmitter. The remote unit RHE 07/08 is for installation in a safe non-Ex area and is connected to the sensor via a single multi-conductor cable. Please note, that the types RHE 07/08 and all sensor articles are available in non Ex-versions (without Exnameplate). The RHE 11 (Ex d) may be installed and operated in hazardous Ex-areas (Zone 1 or 2). Ex-series sensors RHM (with Ex-Label) are, when connected with an Ex- Transmitter, made for installation inside hazardous areas (Ex-zone 0, 1 or 2). The transmitter RHE includes seven printed boards which can be replaced during servicing. The remote electronic unit consists of two bent measuring loops in the shape of an omega.

  • RHE08

The RHEONIK mass flow meter consists of one of the RHM series flow sensors and one RHE series transmitter. The remote unit RHE 07/08 is for installation in a safe non-Ex area and is connected to the sensor via a single multi-conductor cable. Please note, that the types RHE 07/08 and all sensor articles are available in non Ex-versions (without Exnameplate).

  • RHE11

The RHE 11 (Ex d) may be installed and operated in hazardous Ex-areas (Zone 1 or 2). Ex-series sensors RHM (with Ex-Label) are, when connected with an Ex- Transmitter, made for installation inside hazardous areas (Ex-zone 0, 1 or 2). The transmitter RHE includes seven printed boards which can be replaced during servicing. The remote electronic unit consists of two bent measuring loops in the shape of an omega.

  • RHE12

The RHE 12 transmitter is equipped with a 24 VDC mains supply. For trouble-free operation, the power supply must maintain the specified nominal voltage of +- 10%. When connecting the transmitters, always ensure that the power supply is switched off. The earthing for the power supply should be connected using the relevant RHE earthing.

  • RHE14

 The  RHE14  is  low  cost,  compact  and  ideal  for  OEM applications. I/O includes 4-20mA, pulse, flow direction and RS232 serial data. Programming and configuration by SensCom™ software. The RHE06 is ATEX approved for hazardous area installation  and  offers  pulse  output  and  Error  and  Flow Direction.  *The  RHE06F+  has  double  pulse  outputs with 90° phase shift for custody transfer applications

Advertisements

Articles: Flow meters Wiratama

Promag L 400 EH Electromagnetic Flow Meter

The versatile, weight-optimized Promag L is the preferred choice for all standard applications in the water and wastewater industry. Due to its unique lap-joint flange concept, the flowmeter guarantees flexible, easy and economical installation. Promag L 400 saves time and costs thanks to the broad functionality of its water- and wastewater-optimized transmitter. In addition, Heartbeat […]

SITRANS FUS060 Siemens Ultrasonic Flow Meter

The SITRANS FUS060 transmitter is engineered for high performance applications and designed for remote installation in hazardous as well as non-hazardous environments. In addition to the standard outputs, it also offers communication. The SITRANS F US SONO 3100/SITRANS FUS060 flowmeter consists of a sensor and transmitter. For details and information about the transmitter, see SITRANS FUS060 […]

Flow meter air dingin chiller

Sistem pendingin yang banyak di gunakan untuk gedung dengan kapasitas besar seperti hotel, mall serta cold storage biasanya menggunakan chiler sebagai pilihan utama. Untuk bisa memantau performa dari chiller biasanya mengacu pada kapasitas energi yang dihasilkan oleh chille. Karena itu perlu diketahui berapa besar flow rate dengan flow meter air dingin yang  dikalkulasikan dengan besaran […]

Flow meter sistem / pompa pemadam Kebakaran

Flow meter pompa pemadam merupakan flow meter yang digunakan untuk : Mengetes kapasitas sistem pemadam kebakaran Memantau kapasitas pompa sistem pemadam kebakaran Mengetahui performa dari sistem pompa pemadam kebakaran. Flow meter yang digunakan untuk sitem pemadam kebakaran ini menggunakan sitem kerja dari jenis venturi flow meter dengan penunjukan kapasitas berupa dial gauge. Fire pump flow […]

Flow meter ultrasonic 2 Path

Flow meter ultrasonic 2 path atau Double path merupakan jenis flow meter ultrasonic clamp on yang bisa di operasikan atau di instalasi di 2 pipa dengan ukuran dimeter pipa  yang sama maupun ukuran dimeter pipa yang berbeda. Jadi jika kita ingin mengetahui atau mengecek aliran suatu cairan dalam pipa dengan ukuran pipa berbeda ataupun sama […]

 

Ada yang ingin ditanyakan silahkan :

1. Jika ada Pertanyaan tentang Product ataupun harga silahkan langsung hubungi :

 .

2.  Jika ada pertanyaan atau diskusi Tentang tulisan ini silahkan email ke admin@rudywinoto.com

.

Atau silahkan isi kolom dibawah ini dan klik submit  

.  

 

Leave a Reply

Fill in your details below or click an icon to log in:

WordPress.com Logo

You are commenting using your WordPress.com account. Log Out /  Change )

Google+ photo

You are commenting using your Google+ account. Log Out /  Change )

Twitter picture

You are commenting using your Twitter account. Log Out /  Change )

Facebook photo

You are commenting using your Facebook account. Log Out /  Change )

w

Connecting to %s

%d bloggers like this: