Advertisements
News Topic

Electromagnetic Flow Converter

Products // Electromagnetic Flowmeter

ALIAMAG
AMC2100E Series

AMC2100E series Converter With temperature/energy function can be used with AMF series flowmeter in both compact or separate versions.
FEATURES

 Four line LCD display Flowrate/Energy/Totalizer
 Accuracy of +/-0.4% of reading
 Bi-directional flow measurement, current and pulse output
 Large digital display,With temperature/energy function
 99 times records for power on/off
 MODBUS/HART communication
SPECIFICATION

Excitation: Keyboard:
Square wave 4 keys from external for programming 
Display: and display control.
4 lines LCD with back light Low Flow Cutoff:
Line 1 0 to 9.9 %
Date and Time Datalogger Function:
Line 2 99 times records for power on/off
6 digit flowrate Record Data:
7 digit energy value Date/Time when Power on/off
Fault code  99 years flow rate / energy /
Supply temperature Temperature / Total flow / Total energy
Line 3 One Record Data per Hour
9 digit totalizer for forward / reverse flow Damping:
9 digit totalizer for heat / cold  energy 0.1 to 99.9 Second
Fault code content Self Diagnosis:
Return temperature The following error message is 
Line 4 indicated during application
Differential temperature – Coil fail
Unit – Power fail
L/S , L/M , L/H , M3/S , M3/L , M3/H – Output overanged
KW , MW , KJ/H , MJ/H , GJ/H  – Internal error
Measuring Range: – Overflow
Min.  0 to 0.15 m/s – Empty pipe
Max. 0 to 15 m/s Cable Entry:
Accuracy: PG11
+/-0.4% of reading (Velocity >= 0.5 m/s) Protection Class:
+/-0.002 m/s (Velocity < 0.5 m/s) IP 65
Repeatability: Ambient Temperature:
+/-0.1% of reading

-25 to +65 oC
Current Output: Material:
4-20 mA (Isolated) Aluminum Alloy
Load Temperature Input:
Max. 600  PT1000, 2 wire 
Pulse output: Power Supply:
Open collector 90-260 VAC, 50/60 Hz
Rating 24 VDC +/- 10% (Option)
3 to 30 VDC, 20 mA Max.  Power Consumption:
Pulse Rate: 3-17 W (depending on the sensor size)
1)Scale pulse, (Pusle/M3, Pulse/L,
 Other)
Weight:
2)Frequency, 0-5000 Hz 1.4 Kg
Communication: Mounting:
RS 485(MODBUS Protocol) Wall mounting
HART signal Bracket on 2″ pipe
Data Storage:
Operation parameters and totalization 
figures are stored by EEPROM for more
than 10 years
Advertisements

Articles: Rudy flow meter Wiratama

Flow Meter Air Baku PDAM

Flow meter air baku pdam adalah flow meter yang digunakan untuk mengukur debit air dan total volume air baku yang akan di proses guna menghasilkan kwalitas air sesuai standart pdam. Air baku pdam bisanya dimabil dari sungai, bendungan, waduk atau sumur bor dan untuk daerah tertentu mungkin mengambil dari air laut yang di proses menjadi […]

Thermal Mass Compress air and gas flow meters VA500

Flow sensor for compressed air and gas – VA 500 Contrary to the previously used bridge circuit the newly developed evaluation electronics of our flow sensor records all measured values digitally. This leads to a better accuracy also in case of large measuring spans of 1:1000. What are the advantages of our flow measuring technology? […]

Flow meters for compressed air and gas

Fow meters from CS Instruments work according to the calorimetric measuring principle. This means, while measuring the thermal mass flow or standard volume flow, no additional temperature and pressure compensation is necessary. The standard volume is a common volumetric unit used to compare gas quantities at different pressures and temperatures. In order to meet various […]

Batch Controller N series fluidwell

The product group “Batch Controllers” offers multiple batch controllers in the N-Series, F-Series and D-Series product ranges. The batch controllers can be used for accurate dispensing of small amounts of liquids up to the loading of trucks with two-stage control and analog multi-stage control. Specially designed for the delivery of unknown quantities of product is […]

Flow Computers fluidwell

The product group “Flow Computers” offers a unique range of comprehensive solutions to calculate the consumption and net flow at standard conditions or the ratio between two flows. Typical applications are found on board of ships to calculate the fuel consumption, gas flow calculation in power plants and the monitoring of two component blending. The […]

 

Ada yang ingin ditanyakan silahkan

1. Jika ada Pertanyaan tentang Product ataupun harga silahkan langsung hubungi :

2.  Jika ada pertanyaan atau diskusi Tentang tulisan disini silahkan email ke :            admin@rudywinoto.com

  Atau silahkan isi kolom dibawah ini dan klik submit      

  Flowmagflowmasonic          

Leave a Reply

Fill in your details below or click an icon to log in:

WordPress.com Logo

You are commenting using your WordPress.com account. Log Out / Change )

Twitter picture

You are commenting using your Twitter account. Log Out / Change )

Facebook photo

You are commenting using your Facebook account. Log Out / Change )

Google+ photo

You are commenting using your Google+ account. Log Out / Change )

Connecting to %s

%d bloggers like this: