Advertisements
News Topic

Electromagnetic Flow Converter

Products // Electromagnetic Flowmeter

ALIAMAG
AMC2100E Series

AMC2100E series Converter With temperature/energy function can be used with AMF series flowmeter in both compact or separate versions.
FEATURES

 Four line LCD display Flowrate/Energy/Totalizer
 Accuracy of +/-0.4% of reading
 Bi-directional flow measurement, current and pulse output
 Large digital display,With temperature/energy function
 99 times records for power on/off
 MODBUS/HART communication
SPECIFICATION

Excitation: Keyboard:
Square wave 4 keys from external for programming 
Display: and display control.
4 lines LCD with back light Low Flow Cutoff:
Line 1 0 to 9.9 %
Date and Time Datalogger Function:
Line 2 99 times records for power on/off
6 digit flowrate Record Data:
7 digit energy value Date/Time when Power on/off
Fault code  99 years flow rate / energy /
Supply temperature Temperature / Total flow / Total energy
Line 3 One Record Data per Hour
9 digit totalizer for forward / reverse flow Damping:
9 digit totalizer for heat / cold  energy 0.1 to 99.9 Second
Fault code content Self Diagnosis:
Return temperature The following error message is 
Line 4 indicated during application
Differential temperature – Coil fail
Unit – Power fail
L/S , L/M , L/H , M3/S , M3/L , M3/H – Output overanged
KW , MW , KJ/H , MJ/H , GJ/H  – Internal error
Measuring Range: – Overflow
Min.  0 to 0.15 m/s – Empty pipe
Max. 0 to 15 m/s Cable Entry:
Accuracy: PG11
+/-0.4% of reading (Velocity >= 0.5 m/s) Protection Class:
+/-0.002 m/s (Velocity < 0.5 m/s) IP 65
Repeatability: Ambient Temperature:
+/-0.1% of reading

-25 to +65 oC
Current Output: Material:
4-20 mA (Isolated) Aluminum Alloy
Load Temperature Input:
Max. 600  PT1000, 2 wire 
Pulse output: Power Supply:
Open collector 90-260 VAC, 50/60 Hz
Rating 24 VDC +/- 10% (Option)
3 to 30 VDC, 20 mA Max.  Power Consumption:
Pulse Rate: 3-17 W (depending on the sensor size)
1)Scale pulse, (Pusle/M3, Pulse/L,
 Other)
Weight:
2)Frequency, 0-5000 Hz 1.4 Kg
Communication: Mounting:
RS 485(MODBUS Protocol) Wall mounting
HART signal Bracket on 2″ pipe
Data Storage:
Operation parameters and totalization 
figures are stored by EEPROM for more
than 10 years
Advertisements
About Rudy Wiratama (1073 Articles)
Rudy Winoto adalah pemberian orang dari kota minimalis di ujung timur pulau jawa Banyuwangi. Dengan bekal pendidikan pas-pasan di SD Gitik dan SMP Ndelosor dan SMA Rogojampi serta SMADA Bwi mencoba keberuntungan untuk masuk institut teknik di Surabaya dengan Jurusan Perkapalan di ITS Karena suka pindah-pindah kerja dengan alasan super kelasik " Jenuh " membuat saya nggak bisa berkarier dan memaksa saya untuk merintis usaha dengan bermodalkan super nekat, untung2an dan so'-so'an yaitu wiratama mitra abadi. Dan masih terseok-seok dalam rangka mengibarkan bendera wiratama mitra abadi yang base campnya berlokasi di Kalimalang Bekasi. Namun sedikit intisari perjalanan hidup selama ini menyadarkan akan pentingnya untuk melakukan semua hal dengan sedikit lebih baik dan lebih cepat agar bisa memberikan manfaat yang lebih baik untuk masa depan saya dan keluarga. Harpan tarbesar adalah dengan kesadaran tersebut ( masio wes telat ) bisa menghantarkan bendera wiratama ke generasi selanjutnya.

Leave a Reply

Fill in your details below or click an icon to log in:

WordPress.com Logo

You are commenting using your WordPress.com account. Log Out / Change )

Twitter picture

You are commenting using your Twitter account. Log Out / Change )

Facebook photo

You are commenting using your Facebook account. Log Out / Change )

Google+ photo

You are commenting using your Google+ account. Log Out / Change )

Connecting to %s

%d bloggers like this: