News Topic

Water leaks Detection

Ultrasonic flow meters FLOMIC FL5034 and FL5054

Solution for water leaks detectionultrasonic flow meter FL 5034 5054: Solution for water leaks detection

The battery-powered FLOMIC FL5034 and FL5054ultrasonic flow meters are intended for operational and invoicing measurements of instantaneous flow rate,pressure and consumption in water piping in observance of standard EN 14154 in water works, water distribution systems and other industrial applications.
The features of the FLOMIC flow meters make them suitable for water-leak detection and tracking and monitoring of the general condition of water-supply networks.

Ultrasonic flow meter FL 50X4 design

These flow meters are of a compact design with the IP 68 protection class. They are characterised by high measurement accuracy and long-term stability over a wide range of measured values. The meters do not need any external power supply, do not include any moving parts and, have significantly lower hydraulic losses. 
The measurement method utilised by these meters is a single-beam (FL5034) or dual-beam (FL5054) transit-time pulse method based on evaluation of the time needed for an ultrasonic signal to cross the distance between two measuring transductors. In the standard version, the meter measures instantaneous flow rate (in m3/hour) and the total volume of water passed through the meter (in m3) in the given flow direction.
The measured data are converted into passive pulse output signals. The meter output signals can be connected via data transfer systems to remote computer control stations. Flowmeter electronics also includes data storage with various possibility to connect (GSM module, RS232, optical data probe). This feature can be usefull for distance measuring points without electricity.
Flow meters FLOMIC FL 50X4 can effectively save customers costs everywhere, where needs to measure water and is not possible or is expensive to connect to emergy power grid.

Technical parameters

usage measurement of total volume of the water passed through and instantaneous flow rate and pressure
the principle of the measurement transit-time
type – one beam (1B – FL5034) or dual beam  (2B – FL5054)
– compact version
the range of dimensions DN32 to DN300
temperature of measured fluid to 50°C
pressure up to 4.0 MPa
flow sampling period 1 sec
electrical outputs pulse and current
interface optical probe, RS 232, GSM module
data storage data archive
power source Li battery 3.6V, 16Ah, lifetime 6 to 8 years
protection class IP68


Articles: Flow meters Wiratama

Flow meter ultrasonic 2 Path

Flow meter ultrasonic 2 path atau Double path merupakan jenis flow meter ultrasonic clamp on yang bisa di operasikan atau di instalasi di 2 pipa dengan ukuran dimeter pipa  yang sama maupun ukuran dimeter pipa yang berbeda. Jadi jika kita ingin mengetahui atau mengecek aliran suatu cairan dalam pipa dengan ukuran pipa berbeda ataupun sama […]

Flow meter Clamp On Ultrasonic

Flow meter clamp on ultrasonic adalah jenis flow meter yang cara kerjanya menggunakan ultra sound dan cara instalasinya cukup dengan di clamp pada permukaan pipa. Yang dimaksud dengan cara instalasi clamp on adalah saat melakukan instalasi kita tidak perlu memotong pipa maupun melubangi pipa. Dengan melakukan pemotongan pipa atau melubangi pipa, akan menghambat proses produksi […]

Flow Meter Open Channel

Open Channel Flow meter is a flow meter used to measure a flow in an open system wher the flow is due to a height difference such as the flow of water in the river or channel. Flow meter open channel adalah flow meter yang dapat diaplikasikan untuk mengukur aliran dengan kapasitas yang sedang seperti […]

Mengukur Debit Air Pada Kapasitas Aliran Besar

Dalam mengukur debit air pada kapasitas aliran besar mempunyai banyak implikasi terhadap jenis alat ukur atau flow meter, akurasi hasil pengukuran , biaya investasi, waktu instalasi dan maintenance alat ukurnya. Debit air dengan kapasitas aliran besar biasanya banyak di gunakan pada pembangkt lisatrik dalam hal ini biasanya PLTU dan PLTA, Produksi air minum (PDAM) dan […]

Rotary Paddle Level Switch Parker JC7

A level switch is a device used to detect the level of substances such as liquid, chemical solvent, powders, lumps within tanks, silos, and hoppers. In addition, a level switch prevents overfilling of tanks and silos and ensures tanks do not run too low, possibly interrupting production. JB series Rotary Paddle Level Switch Features : […]


Ada yang ingin ditanyakan silahkan :

1. Jika ada Pertanyaan tentang Product ataupun harga silahkan langsung hubungi :


2.  Jika ada pertanyaan atau diskusi Tentang tulisan ini silahkan email ke


Atau silahkan isi kolom dibawah ini dan klik submit  



Leave a Reply

Fill in your details below or click an icon to log in: Logo

You are commenting using your account. Log Out / Change )

Twitter picture

You are commenting using your Twitter account. Log Out / Change )

Facebook photo

You are commenting using your Facebook account. Log Out / Change )

Google+ photo

You are commenting using your Google+ account. Log Out / Change )

Connecting to %s

%d bloggers like this: