In many process boiler systems, zeolite softening of water is not sufficient to meet feed water quality standards. In these cases (typically high pressure boilers up;1000 psig), the water is demineralized. This process removes most of the mineral content of the raw water.

Demineralizers depend upon both cationic and anionic exchange processes. They can be arranged in many different combinations, based upon incoming water contaminants and desired final water quality. By the end of this chapter you should have a basic understanding of what demineralization does, how these systems work, and the basic steps necessary to troubleshoot a system

Demineralization on a commercial scale became possible after resin manufacturers developed methods of mass producing a new form of ion exchange resin. When regenerated with caustic (NaOH), this resin removed silica and carbon dioxide from the effluent of a zeolite resin operated in the hydrogen cycle. A standard cation resin of the type commonly found in zeolite softeners, which is regenerated with sulfuric acid as opposed to salt (hence: hydrogen cycle cation), is called a strong acid cation resin. An anion resin with a strong affinity for silica and carbon dioxide is described as a strong base anion resin. An offshoot of the strong base anion resin development was the production of a chemically different resin with a strong affinity for strong-acid anions: sulfate (SO4), chloride (CI), nitrate (NO3), phosphate (PO4), etc. This was called a weak base resin. The weak base resin does not remove silica or carbon dioxide, as does the strong base resin. Therefore, it cannot be used alone to produce the water purity demanded by high-pressure steam plant operations. Less caustic is required to regenerate the weak base resin and it is often coupled with a strong base resin in the same vessel to produce the most economical anion unit operation. The weak base resin is always loaded into the vessel last when the unit is readied for downflow service.

Putting the weak base resin on top of the anion resin bed uses its higher capacity for strong acid removal to insure that the strong base resin can concentrate on removing the weak acids associated with the carbon dioxide and silica (carbon and silicic acids).

The cation and anion vessels of a demineralizer train are piped in series so that the effluent of the cation unit enters the top of the anion unit and the discharge from the anion unit goes to the treated water header or into a polishing unit.

A discussion of what takes place as the raw water is processed through the various units in a demineralizer may help to explain the resins and their function.  read more……

Articles: Flow meters Wiratama

Flow meter ultrasonic 2 Path

Flow meter ultrasonic 2 path atau Double path merupakan jenis flow meter ultrasonic clamp on yang bisa di operasikan atau di instalasi di 2 pipa dengan ukuran dimeter pipa  yang sama maupun ukuran dimeter pipa yang berbeda. Jadi jika kita ingin mengetahui atau mengecek aliran suatu cairan dalam pipa dengan ukuran pipa berbeda ataupun sama […]

Flow meter Clamp On Ultrasonic

Flow meter clamp on ultrasonic adalah jenis flow meter yang cara kerjanya menggunakan ultra sound dan cara instalasinya cukup dengan di clamp pada permukaan pipa. Yang dimaksud dengan cara instalasi clamp on adalah saat melakukan instalasi kita tidak perlu memotong pipa maupun melubangi pipa. Dengan melakukan pemotongan pipa atau melubangi pipa, akan menghambat proses produksi […]

Flow Meter Open Channel

Open Channel Flow meter is a flow meter used to measure a flow in an open system wher the flow is due to a height difference such as the flow of water in the river or channel. Flow meter open channel adalah flow meter yang dapat diaplikasikan untuk mengukur aliran dengan kapasitas yang sedang seperti […]

Mengukur Debit Air Pada Kapasitas Aliran Besar

Dalam mengukur debit air pada kapasitas aliran besar mempunyai banyak implikasi terhadap jenis alat ukur atau flow meter, akurasi hasil pengukuran , biaya investasi, waktu instalasi dan maintenance alat ukurnya. Debit air dengan kapasitas aliran besar biasanya banyak di gunakan pada pembangkt lisatrik dalam hal ini biasanya PLTU dan PLTA, Produksi air minum (PDAM) dan […]

Rotary Paddle Level Switch Parker JC7

A level switch is a device used to detect the level of substances such as liquid, chemical solvent, powders, lumps within tanks, silos, and hoppers. In addition, a level switch prevents overfilling of tanks and silos and ensures tanks do not run too low, possibly interrupting production. JB series Rotary Paddle Level Switch Features : […]


Ada yang ingin ditanyakan silahkan :

1. Jika ada Pertanyaan tentang Product ataupun harga silahkan langsung hubungi :


2.  Jika ada pertanyaan atau diskusi Tentang tulisan ini silahkan email ke


Atau silahkan isi kolom dibawah ini dan klik submit  



Leave a Reply

Fill in your details below or click an icon to log in: Logo

You are commenting using your account. Log Out / Change )

Twitter picture

You are commenting using your Twitter account. Log Out / Change )

Facebook photo

You are commenting using your Facebook account. Log Out / Change )

Google+ photo

You are commenting using your Google+ account. Log Out / Change )

Connecting to %s

%d bloggers like this: